Brilliance CT 64-Channel configuration spare parts
Browse available spare parts and part numbers for this Philips CT system.
Filter this model by part category.
| Part no | Description | Brand |
|---|---|---|
| 453567062391 | A-Plane Collimator BR40 and 64 | Philips |
| 453567139462 | ACS Assembly w/ Intr. Driven Motion | Philips |
| 453567026041 | ACS Software Tool Kit | Philips |
| 453567316332 | Bearing/Slipring Replacement Kit | Philips |
| 453566489331 | Bracket, ACS Mtg | Philips |
| 455012004232 | CDMP Board Assembly | Philips |
| 453566457351 | Couch Control PCB Assy with CPM2 part numbers — choose your model | Philips |
| 453566457352 | Couch Control PCB Assy with CPM2 part numbers — choose your model | Philips |
| 453567006131 | Couch Control PCB Assy without CPM2 part numbers — choose your model | Philips |
| 453567053781 | Couch Control PCB Assy without CPM2 part numbers — choose your model | Philips |
| 453566460201 | Couch Power Board Assy. | Philips |
| 453567057163 | FRC Assembly | Philips |
| 453567246491 | GHOST Fuse, 250mA, 250V | Philips |
| 453567030531 | High Speed Starter | Philips |
| 453566502361 | Inverter Panel Assy | Philips |
| 453567030071 | MODULE, ROTOR OPTICAL LASER TRANSMITTER BOX | Philips |
| 453567030081 | MODULE, STATOR OPTICAL LASER RECEIVER BOX | Philips |
| 453567110321 | SG164 GHOST Assembly | Philips |
| 453567012011 | Slip Ring | Philips |
| 453566146401 | Slip Ring Fuses, 40A | Philips |
| 453567050121 | Slip Ring Lubricant, 20ML, ES385 | Philips |
| 453567459911 | Slipring Cleaning Brush | Philips |
| 453567459841 | Slipring Cleaning Tool Assembly | Philips |
| 453567030532 | Starter w/ Watchdog & Dual Tube Firmware | Philips |
| 453567050131 | Syringe, 100 mL, Slip Ring Lubricant | Philips |
| 455018001011 | 1 GB Intel Dual Port LAN Card | Philips |
| 453567385731 | 12V DC power supply | Philips |
| 455012005321 | 2U PANEL ASSEMBLY (FILLER PANEL) | Philips |
| 453567399251 | Absolute Encoder Assy | Philips |
| 453567069982 | AC Control Unit PCB | Philips |
| 453567119771 | ACQUISITOR PCB ASSY., 5.3 GBIT | Philips |
| 453567028511 | Anode Power Module | Philips |
| 453567028512 | APM Assembly with Dual Tube Stand | Philips |
| 455012005212 | Assembly, Connectors Panel | Philips |
| 455012005122 | Assembly, Fan Support | Philips |
| 453567399181 | Assembly, Horizontal Brake, 10 mm Bore | Philips |
| 455014001011 | Assembly, I-Box PCB | Philips |
| 453566460131 | Assembly, Main Drive Processor (Includes CPM Assem | Philips |
| 455012005112 | Assembly, Power Distribution Unit (PDU) Box | Philips |
| 453567036891 | Assembly, Power Supply 5VDC | Philips |
About Brilliance CT 64-Channel configuration spare parts
Every listing in the Brilliance CT 64-Channel configuration listing carries the OEM part number, part name and, where available, the FRU type and board-level notes, so you can match the exact revision fitted in your scanner before you order. Parts are supplied on exchange basis only against return of your original unit, and each unit is bench tested and packed in ESD-safe material before dispatch.
Compatibility is listed against Brilliance CT 64-Channel configuration and closely related Philips CT configurations. Because Philips and GE re-use assemblies across generations, many boards, cables, detector modules and power components carry equivalent alternative numbers — send us the number stamped on your existing part and we will confirm the correct fit and any superseding revision.
Service availability covers all-India supply with field engineer support for installation, calibration and post-fit verification, plus AMC/CMC contracts, breakdown call-outs and exchange supply of tested assemblies. Share your system model and part number for current stock position, lead time and pricing.
Our engineers came out of the Philips Healthcare and GE Healthcare service organisations, so a part order can be paired with on-site fitment: fault confirmation before the part ships, replacement under proper ESD and high-voltage precautions, recalibration and image quality checks afterwards, and a signed service report with the readings recorded for your NABH and AERB documentation. All assemblies are supplied on exchange basis only — your original unit is returned to us — and we do not undertake board repair for customers.
Need a quote? Send a part query.