All spare parts

Brilliance 6/10/16/16P (Air) spare parts

Browse available spare parts and part numbers for this Philips CT system.

Filter this model by part category.

Part noDescriptionBrand
453566491971CBL., Bulk 24V SupplyPhilips
453566491801CBL., CT Absolute EncoderPhilips
453566492021CBL., CT BreakPhilips
453566492031CBL., CT Clutch RelayPhilips
453566491961CBL., CT Limit Relay FDBK & TapePhilips
453566491921CBL., CT Motor EncoderPhilips
453566491821CBL., CT Position EncoderPhilips
453566491831CBL., CT Position Ref.Philips
453566491911CBL., CT Tape SwitchPhilips
453566491931CBL., DC PowerPhilips
453566491991CBL., I/O XPhilips
453566492011CBL., I/O YPhilips
453566492041CBL., Motor Relay PowerPhilips
453566492001CBL., RS422 & Backup PowerPhilips
453566491981CBL., Scissor GroundPhilips
453566491891CBL., SSR ControlPhilips
453566491851CBL., Vertical Limits/BrakePhilips
453566491871CBL., Vertical PowerPhilips
453566491881CBL., Xformer PowerPhilips
453567477512CD Set, Brilliance 6-16P, v. 2.3.0.13022Philips
453567405152CD Set, Brilliance 6-16P, V2.2.2.13005Philips
453567405012CD Set, Brilliance 6-16P, V2.2.2.13005 upgradePhilips
453567425031CD Set, Brilliance 6-16P, V2.2.5Philips
453567467171CD Set, Brilliance v 2.2.7.13013Philips
453567110531CD-ROM DrivePhilips
455012305121CIB CablePhilips
453566501721Circuit BreakerPhilips
453567105501Circuit Breaker, 7A 1 PolePhilips
453567402301CIRS Ethernet 16-port SwitchPhilips
453566494823Clutch, Horizontal DrivePhilips
455012305141Com 2 CablePhilips
453579519600Compound - Dow Corning #4Philips
453567412831Computer, QBMapPhilips
453567015951Cone, RearPhilips
453567368111Conn, 20A-250V, Twist Lock, NEMA L6-20RPhilips
455012305271Console SVGA-1 2.00 M CablePhilips
455012305261Console SVGA-1 2.70 M CablePhilips
453566495141Controller, Main Drive Primary ControllerPhilips
453567023211Controller, Utility/Console XFMRPhilips
453567110511Cooling Fan 120mmPhilips
Page 12 of 21

About Brilliance 6/10/16/16P (Air) spare parts

Every listing in the Brilliance 6/10/16/16P (Air) listing carries the OEM part number, part name and, where available, the FRU type and board-level notes, so you can match the exact revision fitted in your scanner before you order. Parts are supplied on exchange basis only against return of your original unit, and each unit is bench tested and packed in ESD-safe material before dispatch.

Compatibility is listed against Brilliance 6/10/16/16P (Air) and closely related Philips CT configurations. Because Philips and GE re-use assemblies across generations, many boards, cables, detector modules and power components carry equivalent alternative numbers — send us the number stamped on your existing part and we will confirm the correct fit and any superseding revision.

Service availability covers all-India supply with field engineer support for installation, calibration and post-fit verification, plus AMC/CMC contracts, breakdown call-outs and exchange supply of tested assemblies. Share your system model and part number for current stock position, lead time and pricing.

Our engineers came out of the Philips Healthcare and GE Healthcare service organisations, so a part order can be paired with on-site fitment: fault confirmation before the part ships, replacement under proper ESD and high-voltage precautions, recalibration and image quality checks afterwards, and a signed service report with the readings recorded for your NABH and AERB documentation. All assemblies are supplied on exchange basis only — your original unit is returned to us — and we do not undertake board repair for customers.

Need a quote? Send a part query.