Philips Ingenuity CT spare parts
Browse available spare parts and part numbers for this Philips CT system.
Philips Ingenuity CT uses the same spare parts as the Brilliance 64-Channel (Air) system, so the part numbers below are valid Ingenuity alternatives — apart from six Ingenuity-specific items, listed at the bottom of this page for enquiry.
Filter this model by part category.
| Part no | Description | Brand |
|---|---|---|
| 455012305221 | CRC Rack Digital (1Ferrite) Svga Male-Male. | Philips |
| 455012301091 | CRC Rack Lan 1GB RJ45 Gategory 5. | Philips |
| 455012305231 | CRC Rack PS2-KB/Mo. (Male - Fe. Panel). | Philips |
| 453567033721 | CT Main Drive Belt Tensioning Tool | Philips |
| 453566284931 | CT Service Tool Kit | Philips |
| 455012305131 | CT-Box Keys Serial Cable | Philips |
| 451214872141 | CU 6100 (Cooling Unit) | Philips |
| 453567030281 | Cushion, PT Support, Yellow | Philips |
| 455013000121 | Dell 670, 2 CPU, 3.4 GHz, 2MB | Philips |
| 455011305081 | Dell 690 single CPU with RAID | Philips |
| 455011305061 | Dell 690 single CPU without RAID | Philips |
| 453567067861 | Diagnostic S/W, "CD BR 16P Utilities" | Philips |
| 453567450801 | Diaphram, Splash Protection | Philips |
| 453567404351 | Display, 19" LCD | Philips |
| 453567495101 | DMS Pin Alignment Kit | Philips |
| 455011508021 | DMS service tool kit (without DMS) | Philips |
| 455012104401 | DMS UHR Adjustement Jig | Philips |
| 453567149411 | Drill Template, J-Blk Cover Retainer | Philips |
| 453567149141 | Drill, #29 | Philips |
| 453566502751 | Dual Tilt Drive Interface Bd. | Philips |
| 453567102701 | Duct, Heat Exchanger | Philips |
| 455013020751 | DVD / CD Burner and Pack | Philips |
| 453567278521 | E-Stop Label | Philips |
| 453566420731 | E-Stop Switch | Philips |
| 455012001601 | ECG Cart | Philips |
| 455018001051 | ECG Monitor English | Philips |
| 455012301901 | ECG Monitor trigger 4M Cable | Philips |
| 453567009971 | ECG monitoring I/O panel | Philips |
| 455011509711 | ECG3 Lead Grabber Leadset, AAMI (only North Americ | Philips |
| 455011509721 | ECG3 Lead Grabber Leadset, IEC (rest of the world) | Philips |
| 453566500911 | Encoder, CT Absolute | Philips |
| 453566500901 | Encoder, CT Positional | Philips |
| 453566489441 | EOD 9.1 GB | Philips |
| 453567143981 | Epoxy Floor Level Kit | Philips |
| 453566224761 | ESD protection Kit | Philips |
| 455011202611 | Ethernet Switch 10/100 Mbps (CISCO) | Philips |
| 453567055342 | Exhaust Fan | Philips |
| 453567475561 | External Battery Pack, 2.2 KVA, UPS | Philips |
| 453567410841 | External Battery Pack, 3KVA, UPS, 72VDC | Philips |
| 455012001031 | Eye Phantom | Philips |
Ingenuity-specific parts — enquire
These items are specific to this system and are not interchangeable. Send us the request and our parts desk will reply with the correct part number, price and lead time.
Transmitter box
Ingenuity-specific — not interchangeable with Brilliance 64
Receiver box
Ingenuity-specific — not interchangeable with Brilliance 64
MRC 880 CT tube
Ingenuity-specific X-ray tube
80 kW Cathode Power Module
Ingenuity-specific power module
80 kW Anode Power Module
Ingenuity-specific power module
High Speed Starter
Ingenuity-specific starter
About Philips Ingenuity CT spare parts
Every listing in the Philips Ingenuity CT listing carries the OEM part number, part name and, where available, the FRU type and board-level notes, so you can match the exact revision fitted in your scanner before you order. Parts are supplied on exchange basis only against return of your original unit, and each unit is bench tested and packed in ESD-safe material before dispatch.
Compatibility is listed against Philips Ingenuity CT and closely related GE CT configurations. Because Philips and GE re-use assemblies across generations, many boards, cables, detector modules and power components carry equivalent alternative numbers — send us the number stamped on your existing part and we will confirm the correct fit and any superseding revision.
Service availability covers all-India supply with field engineer support for installation, calibration and post-fit verification, plus AMC/CMC contracts, breakdown call-outs and exchange supply of tested assemblies. Share your system model and part number for current stock position, lead time and pricing.
Our engineers came out of the Philips Healthcare and GE Healthcare service organisations, so a part order can be paired with on-site fitment: fault confirmation before the part ships, replacement under proper ESD and high-voltage precautions, recalibration and image quality checks afterwards, and a signed service report with the readings recorded for your NABH and AERB documentation. All assemblies are supplied on exchange basis only — your original unit is returned to us — and we do not undertake board repair for customers.
Need a quote? Send a part query.