All spare parts

Philips Ingenuity CT spare parts

Browse available spare parts and part numbers for this Philips CT system.

Philips Ingenuity CT uses the same spare parts as the Brilliance 64-Channel (Air) system, so the part numbers below are valid Ingenuity alternatives — apart from six Ingenuity-specific items, listed at the bottom of this page for enquiry.

Filter this model by part category.

Part noDescriptionBrand
453567030941Cable, ACQ to Mango ACQ adapterPhilips
453567382551Cable, Adapter for Rotor Optical TX BoxPhilips
453567038911Cable, Appl Ref Convrt Pwr SupPhilips
453566501631Cable, CAN Thost to SSLIPhilips
453566496221Cable, DC Common GroundPhilips
453567072892Cable, DMC to Optical Tx Aux. Rotor PositionPhilips
453567038841CABLE, DMS PS-1 POWERPhilips
453567038851CABLE, DMS PS-2 POWERPhilips
453567038861CABLE, DMS PS-3 DC POWERPhilips
453567038871CABLE, DMS PS-4 DC POWERPhilips
L23137Cable, Dual Tilt pot to ThostPhilips
L23477Cable, ECG to GantryPhilips
453566491751Cable, EMI Filter to Main Drive TransformerPhilips
453567429841Cable, Fan - Rear DoorPhilips
453567435071Cable, Float SwitchPhilips
453567435061Cable, Footswitch I/FPhilips
453566496231Cable, Gantry Base to Main GroundPhilips
453567435051Cable, Gantry I/F to FootswitchPhilips
453567368121Cable, Gantry XFMR to 3 KVA UPS InletPhilips
453566501691Cable, Ghoast to ACCU E-Stop.Philips
L23524Cable, Gnd, Gantry to CouchPhilips
453567448511Cable, L/R Rear SW DataPhilips
L23083Cable, Left Mtr dr to Richt Mtr drPhilips
453566491301Cable, Main Drive Transformer to Fuse CntactorPhilips
453567037881Cable, Medrad Envision AdapterPhilips
453567015591Cable, Mobile, SDB to CT Box ExtensionPhilips
453567449511Cable, Panning Handle ReceptaclePhilips
453566491711Cable, Resistance Box to SpindleblokPhilips
L23006Cable, Right gantry to main gndPhilips
453567412551Cable, SCSI 2-Device, 5 in. spacing, 27 in. longPhilips
453567045961Cable, SG164 ECG I/OPhilips
453567106291Cable, Shut Down, PS-2Philips
453566501611Cable, TDP to DTDIB Control 2.Philips
453566501601Cable, Thost to DTDIB Control 1.Philips
453566591601Cable, Thost to Tilt dr ifacePhilips
L23158Cable, Tilt, Misc. AC supplies wirePhilips
L23318Cable, Vert Mon Bd to Regen Bd.Philips
L23317Cable, Vert Mon Bd to Relay Bd.Philips
453566502211Cam, Tilt LimitPhilips
455012305151CAN Bus CablePhilips
Page 9 of 21

Ingenuity-specific parts — enquire

These items are specific to this system and are not interchangeable. Send us the request and our parts desk will reply with the correct part number, price and lead time.

  • Transmitter box

    Ingenuity-specific — not interchangeable with Brilliance 64

  • Receiver box

    Ingenuity-specific — not interchangeable with Brilliance 64

  • MRC 880 CT tube

    Ingenuity-specific X-ray tube

  • 80 kW Cathode Power Module

    Ingenuity-specific power module

  • 80 kW Anode Power Module

    Ingenuity-specific power module

  • High Speed Starter

    Ingenuity-specific starter

About Philips Ingenuity CT spare parts

Every listing in the Philips Ingenuity CT listing carries the OEM part number, part name and, where available, the FRU type and board-level notes, so you can match the exact revision fitted in your scanner before you order. Parts are supplied on exchange basis only against return of your original unit, and each unit is bench tested and packed in ESD-safe material before dispatch.

Compatibility is listed against Philips Ingenuity CT and closely related GE CT configurations. Because Philips and GE re-use assemblies across generations, many boards, cables, detector modules and power components carry equivalent alternative numbers — send us the number stamped on your existing part and we will confirm the correct fit and any superseding revision.

Service availability covers all-India supply with field engineer support for installation, calibration and post-fit verification, plus AMC/CMC contracts, breakdown call-outs and exchange supply of tested assemblies. Share your system model and part number for current stock position, lead time and pricing.

Our engineers came out of the Philips Healthcare and GE Healthcare service organisations, so a part order can be paired with on-site fitment: fault confirmation before the part ships, replacement under proper ESD and high-voltage precautions, recalibration and image quality checks afterwards, and a signed service report with the readings recorded for your NABH and AERB documentation. All assemblies are supplied on exchange basis only — your original unit is returned to us — and we do not undertake board repair for customers.

Need a quote? Send a part query.