Philips CT part numbers starting 45356650
78 Philips CT scanner spare part numbers begin with 45356650. Open a part number for fitment, description and an availability enquiry.
- 453566500221 — FOC D514
- 453566500231 — PCB MCU RTC
- 453566500251 — ADU D513 CPL
- 453566500331 — Transmitter
- 453566500341 — Receiver
- 453566500351 — GPC
- 453566500361 — Main Control Board
- 453566500421 — 7200 DMS Single ADM
- 453566500521 — U-type DMS 6 Modules Kit
- 453566500541 — 7200 RCOM Assembly
- 453566500561 — MBR Card
- 453566500562 — Assembly, Right Motherboard
- 453566500571 — MBL Card
- 453566500572 — Assembly, Left Motherboard
- 453566500671 — SCSI Control IRS
- 453566500801 — MATTRESS SERVICE KIT
- 453566500811 — Falcon Acquisitor
- 453566500901 — Encoder, CT Positional
- 453566500911 — Encoder, CT Absolute
- 453566501021 — IRS Fan
- 453566501151 — Microphone B311 with CBL W383
- 453566501161 — Microphone B312 with CBL W384
- 453566501181 — Microphone B315 with CBL W387
- 453566501191 — Microphone B314 with CBL W388
- 453566501221 — Balancing Sensor
- 453566501241 — Brake Assembly
- 453566501311 — PT-Horizontal
- 453566501401 — CBL, APM TO FRC
- 453566501551 — CBL, HEAT XCHG PUMP INTERFAC
- 453566501591 — CBL, SPINDLEBLK ANALOG I/O-MD
- 453566501601 — Cable, Thost to DTDIB Control 1.
- 453566501611 — Cable, TDP to DTDIB Control 2.
- 453566501631 — Cable, CAN Thost to SSLI
- 453566501641 — CBL, ROTATION CTR TO GHOST
- 453566501691 — Cable, Ghoast to ACCU E-Stop.
- 453566501721 — Circuit Breaker
- 453566501741 — Fuse F1 - F3, LPJ-20SP, 600V, 20A
- 453566501951 — Couch Relay Bd. Assy.
- 453566502001 — Resolver
- 453566502022 — Phantom Holder Assy, Carbon Top
- 453566502051 — Gantry Lifting Assy.
- 453566502101 — Motor Sheave Alignment Tool
- 453566502151 — Resolver Cover
- 453566502211 — Cam, Tilt Limit
- 453566502361 — Inverter Panel Assy
- 453566502381 — Tilt Relay Safety Assy
- 453566502391 — Tilt Drive Processor Assy
- 453566502401 — Vert. Couch Monitor Board
- 453566502431 — Vert Encoder Assy
- 453566502521 — Turnbuckel
- 453566502531 — Linear Actuator, SKF, RH
- 453566502541 — Linear Actuator, SKF, LH
- 453566502591 — Patient CushionKit w/o Straps
- 453566502661 — Philips Mousepad
- 453566502751 — Dual Tilt Drive Interface Bd.
- 453566502761 — Variable Speed Motor Controller
- 453566502771 — Dual Tilt Pot Assy
- 453566502801 — CBL ECG/JST (2M)
- 453566502911 — System Control Board
- 453566503121 — Fuse, F303, 20A
- 453566503131 — Fuses, 15A Type CC
- 453566503142 — Fan, Tube Axial
- 453566503371 — DETECTOR CABLE
- 453566503471 — Limit Switch, Horizontal In
- 453566503511 — Tilt Relay
- 453566503521 — Auxiliary Contact, Side Mounting, N.C.
- 453566503531 — Belt, Angulation Pot
- 453566503541 — Fuse 2A SB
- 453566503571 — Tilt Resistor
- 453566503601 — Block, Central Ground
- 453566503671 — Breaker, 10A
- 453566503691 — Breaker, 3A
- 453566503721 — Line Filter, 3-Phase
- 453566503741 — 4 Output DC Supply
- 453566503761 — Vertical Transducer
- 453566503811 — Cotter Pin, Linear Actuator
- 453566503861 — DC-Control Stat D451
- 453566504191 — EOD 9 1 External Drive
About part numbers starting 45356650
Every listing in this 45356650 part-number group carries the OEM part number, part name and, where available, the FRU type and board-level notes, so you can match the exact revision fitted in your scanner before you order. Parts are supplied on exchange basis only against return of your original unit, and each unit is bench tested and packed in ESD-safe material before dispatch.
Compatibility is listed against Philips and GE CT scanner platforms that share this number series. Because Philips and GE re-use assemblies across generations, many boards, cables, detector modules and power components carry equivalent alternative numbers — send us the number stamped on your existing part and we will confirm the correct fit and any superseding revision.
Service availability covers all-India supply with field engineer support for installation, calibration and post-fit verification, plus AMC/CMC contracts, breakdown call-outs and exchange supply of tested assemblies. Share your system model and part number for current stock position, lead time and pricing.
Our engineers came out of the Philips Healthcare and GE Healthcare service organisations, so a part order can be paired with on-site fitment: fault confirmation before the part ships, replacement under proper ESD and high-voltage precautions, recalibration and image quality checks afterwards, and a signed service report with the readings recorded for your NABH and AERB documentation. All assemblies are supplied on exchange basis only — your original unit is returned to us — and we do not undertake board repair for customers.
