Philips CT part numbers starting 45356703
59 Philips CT scanner spare part numbers begin with 45356703. Open a part number for fitment, description and an availability enquiry.
- 453567030071 — MODULE, ROTOR OPTICAL LASER TRANSMITTER BOX
- 453567030081 — MODULE, STATOR OPTICAL LASER RECEIVER BOX
- 453567030281 — Cushion, PT Support, Yellow
- 453567030531 — High Speed Starter
- 453567030532 — Starter w/ Watchdog & Dual Tube Firmware
- 453567030571 — CBL, FRC to XRT Thermal Switch
- 453567030771 — CBL, Ghost to +12VPS
- 453567030861 — Cable, GHOST to Sig brush CTRL Link
- 453567030931 — Cbl, Ghost to ACQ - Interconnect
- 453567030941 — Cable, ACQ to Mango ACQ adapter
- 453567031431 — Wireset, 480VAC Upper Brushblock
- 453567031671 — FSE Biohazar Kit
- 453567032051 — Tape Switch, 17"
- 453567032061 — CBL, Handle Tape Switch
- 453567032331 — X-direction Shield Wrench
- 453567032501 — Strap Pad Assy Installation Tool
- 453567032591 — LOGO D1
- 453567032651 — CBL, Heat Xchg Fans Interface
- 453567032661 — Assy, Servo Transformer
- 453567032881 — Laser source block Assy
- 453567033081 — CBL, Footswitch, Includes four 26 inch tape switch
- 453567033091 — 1/4 Amp Fuse
- 453567033271 — CBL, ACCU to Suite Annunciator
- 453567033431 — CBL, CPM to FRC
- 453567033441 — Laser Assy, RH Front Cover
- 453567033721 — CT Main Drive Belt Tensioning Tool
- 453567033771 — CBL, ACCU to Main Drive Transformer
- 453567033891 — CBL, 12V Power Supply to T-Host
- 453567034081 — CBL, CAN, Thost to Mhost
- 453567034191 — CBL, Serial I-Box to Ghost
- 453567034301 — CBL, I-Box to Ghost
- 453567034411 — Fiber, Optic Single, GSU to RECON, 100 ft.
- 453567034741 — Plate, Shim
- 453567036791 — CBL, Signal Brush Block to TDP CAN
- 453567036801 — CBL, Signal BB to Ghost Control Link
- 453567036891 — Assembly, Power Supply 5VDC
- 453567036961 — Cover, Base Plate Access
- 453567037011 — CBL, 75Ft Power Inlet (Console & Recon UPS)
- 453567037021 — CBL, 75Ft Power Outlet (Console & Recon UPS)
- 453567037031 — CBL, UPS to Console Serial
- 453567037181 — CBL, DMP to UHR
- 453567037801 — Ship with Hardware, Couch/Gantry
- 453567037811 — Plug 1.0", hole, mushroom
- 453567037821 — Plug 5/8", hole, mushroom
- 453567037861 — Cable Assy, Injector
- 453567037871 — Liebel-Flarsheim Injector Adapter
- 453567037881 — Cable, Medrad Envision Adapter
- 453567037891 — CBL, GHOST INTERNAL INJECTOR, ADAPTOR
- 453567038002 — Tape Switch Transition Board
- 453567038731 — CIRS -3DBP, POWER BOARD - 2 CHANNEL
- 453567038841 — CABLE, DMS PS-1 POWER
- 453567038851 — CABLE, DMS PS-2 POWER
- 453567038861 — CABLE, DMS PS-3 DC POWER
- 453567038871 — CABLE, DMS PS-4 DC POWER
- 453567038881 — CBL, DMC To DMP Signal
- 453567038891 — CBL, DC Power Short
- 453567038901 — Cbl, Fans
- 453567038911 — Cable, Appl Ref Convrt Pwr Sup
- 453567038921 — CBL, RCOM Control
About part numbers starting 45356703
Every listing in this 45356703 part-number group carries the OEM part number, part name and, where available, the FRU type and board-level notes, so you can match the exact revision fitted in your scanner before you order. Parts are supplied on exchange basis only against return of your original unit, and each unit is bench tested and packed in ESD-safe material before dispatch.
Compatibility is listed against Philips and GE CT scanner platforms that share this number series. Because Philips and GE re-use assemblies across generations, many boards, cables, detector modules and power components carry equivalent alternative numbers — send us the number stamped on your existing part and we will confirm the correct fit and any superseding revision.
Service availability covers all-India supply with field engineer support for installation, calibration and post-fit verification, plus AMC/CMC contracts, breakdown call-outs and exchange supply of tested assemblies. Share your system model and part number for current stock position, lead time and pricing.
Our engineers came out of the Philips Healthcare and GE Healthcare service organisations, so a part order can be paired with on-site fitment: fault confirmation before the part ships, replacement under proper ESD and high-voltage precautions, recalibration and image quality checks afterwards, and a signed service report with the readings recorded for your NABH and AERB documentation. All assemblies are supplied on exchange basis only — your original unit is returned to us — and we do not undertake board repair for customers.
