Philips CT part numbers starting 45356704
26 Philips CT scanner spare part numbers begin with 45356704. Open a part number for fitment, description and an availability enquiry.
- 453567041591 — SG164 Mylar Floor Template Gantry & Couch w/shippi
- 453567041721 — Belt replacement kit
- 453567041811 — O-ring belt, timing
- 453567041821 — Z-Adjustment Straddle Plate
- 453567041841 — Z-Adjustment Static Block
- 453567042371 — CBL, 12VPS to Optical RX
- 453567042411 — CBL, Vertical Limits/Brake
- 453567042461 — CBL, Ground, FRC to Rotor
- 453567044421 — CBL, CONSOLE TRANSFORMER TO CONSOLE
- 453567044431 — CBL, CONSOLE TRANSFORMER TO RECON
- 453567044891 — CBL, Tape Switch Interconnect
- 453567045171 — Horizontal Brake
- 453567045761 — CBL, Ghost Internal CCT Adapter
- 453567045921 — CBL, Right column to Main gnd
- 453567045961 — Cable, SG164 ECG I/O
- 453567045971 — Head Holder, Flat
- 453567046062 — Quick Lock Assembly
- 453567046081 — Head Holder, Standard
- 453567046131 — Block, Lock Stop
- 453567046162 — A-Plane Collimator
- 453567046181 — CABLE, 120VAC FRC TO DMC PS
- 453567046221 — Table Extension Assy
- 453567046401 — RECEIVER FIBER OPTICS, HARNESS
- 453567047631 — CBL, RCOM To Optical Transmitter
- 453567047641 — CBL, DPU 1 TO RCOM
- 453567049571 — Arm Rest
About part numbers starting 45356704
Every listing in this 45356704 part-number group carries the OEM part number, part name and, where available, the FRU type and board-level notes, so you can match the exact revision fitted in your scanner before you order. Parts are supplied on exchange basis only against return of your original unit, and each unit is bench tested and packed in ESD-safe material before dispatch.
Compatibility is listed against Philips and GE CT scanner platforms that share this number series. Because Philips and GE re-use assemblies across generations, many boards, cables, detector modules and power components carry equivalent alternative numbers — send us the number stamped on your existing part and we will confirm the correct fit and any superseding revision.
Service availability covers all-India supply with field engineer support for installation, calibration and post-fit verification, plus AMC/CMC contracts, breakdown call-outs and exchange supply of tested assemblies. Share your system model and part number for current stock position, lead time and pricing.
Our engineers came out of the Philips Healthcare and GE Healthcare service organisations, so a part order can be paired with on-site fitment: fault confirmation before the part ships, replacement under proper ESD and high-voltage precautions, recalibration and image quality checks afterwards, and a signed service report with the readings recorded for your NABH and AERB documentation. All assemblies are supplied on exchange basis only — your original unit is returned to us — and we do not undertake board repair for customers.
