Philips CT part numbers starting 45356709
30 Philips CT scanner spare part numbers begin with 45356709. Open a part number for fitment, description and an availability enquiry.
- 453567090871 — Plug 5/8", hole short, silver
- 453567091121 — Fiber Assy. Source, Rotor, Transmit
- 453567091311 — CBL, Ghost to Front/Rear Estop
- 453567091341 — CBL, Left/Right Rear Estop
- 453567091351 — CBL, Left/Rear Sw Data
- 453567091361 — CBL, Right/Rear Sw Data
- 453567091381 — CBL, Left/Right Rear Switch Data
- 453567091391 — CBL, Gantry Audio to Spkr/MIC Front
- 453567091401 — CBL, Gantry Audio to SPKR/MIC Rear
- 453567091411 — CBL, Gantry RR Spkr/Mic Ext
- 453567091421 — CBL, Ghost to Display Control
- 453567091431 — CBL, R_ENA, Ghost to Display Control
- 453567091441 — CBL, L_ENA, Ghost to Display Control
- 453567091451 — CBL, 12VPS to Display Control
- 453567091471 — CBL, Disp/SW Cont to Gantry Left Disp
- 453567091481 — CBL, Disp/SW Cont to Gntry Right Disp
- 453567091511 — CBL, Disp/SW Cont to Left SW PNL
- 453567091521 — CBL, Disp/SW Cont to RT SW PNL
- 453567091962 — Brilliance (Air) Therapy Top
- 453567093501 — Laser Safety Glasses, CE CERTIFIED
- 453567093571 — CIRS 3U Server S1C
- 453567098101 — R2D Assembly
- 453567098151 — Prism Holder Assy. Stator
- 453567098161 — Fiber Assy., Bi-Dir, Rotor Receive , 10 Fibers
- 453567098171 — Fiber Assy., Bi-Dir, Stator Receive, 5 Fibers
- 453567098181 — Fiber Assy., Data, Receive Stator, 4 Fibers
- 453567098191 — Bi-Directional Transceiver
- 453567098201 — Module, Optical TX, Rotor
- 453567098231 — Prism Holder Assy. Rotor
- 453567099401 — Motor Coupling
About part numbers starting 45356709
Every listing in this 45356709 part-number group carries the OEM part number, part name and, where available, the FRU type and board-level notes, so you can match the exact revision fitted in your scanner before you order. Parts are supplied on exchange basis only against return of your original unit, and each unit is bench tested and packed in ESD-safe material before dispatch.
Compatibility is listed against Philips and GE CT scanner platforms that share this number series. Because Philips and GE re-use assemblies across generations, many boards, cables, detector modules and power components carry equivalent alternative numbers — send us the number stamped on your existing part and we will confirm the correct fit and any superseding revision.
Service availability covers all-India supply with field engineer support for installation, calibration and post-fit verification, plus AMC/CMC contracts, breakdown call-outs and exchange supply of tested assemblies. Share your system model and part number for current stock position, lead time and pricing.
Our engineers came out of the Philips Healthcare and GE Healthcare service organisations, so a part order can be paired with on-site fitment: fault confirmation before the part ships, replacement under proper ESD and high-voltage precautions, recalibration and image quality checks afterwards, and a signed service report with the readings recorded for your NABH and AERB documentation. All assemblies are supplied on exchange basis only — your original unit is returned to us — and we do not undertake board repair for customers.