Philips CT part numbers starting 45411019
118 Philips CT scanner spare part numbers begin with 45411019. Open a part number for fitment, description and an availability enquiry.
- 454110190011 — Patient table AC Power Cable
- 454110190012 — Patient table AC Power Cable
- 454110190021 — Cable Between Power and Switch Power Supply
- 454110190031 — Cable Between Transformer and Switch Power Supply
- 454110190032 — Cable Between Transformer and Switch Power Supply
- 454110190041 — Power Cable Between Switch power Supply and Actuat
- 454110190051 — Power Cable Between Switch Power Supply and Safty
- 454110190061 — Power Cable Between DC 24V Switch power Supply and
- 454110190071 — Power Cable Between DC 5V Switch Power and Motion
- 454110190081 — Power Cable Between Motion Control Board and Servi
- 454110190091 — Signal Cable Between Motion Control Board and Serv
- 454110190101 — Signal Cable Between Motion Control Board and SERV
- 454110190102 — Signal Cable Between Motion Control Board and SERV
- 454110190111 — Patient Table Limit Switch Cable1
- 454110190112 — Patient Table Limit Switch Cable1
- 454110190121 — Patient Table Limit Switch Cable2
- 454110190122 — Patient Table Limit Switch Cable2
- 454110190131 — Patient Table Limit Switch Cable3
- 454110190161 — Host AC Cable
- 454110190181 — Electricity Sensor Cable
- 454110190182 — Electricity Sensor Cable
- 454110190191 — Right Emergency Switch Cable
- 454110190201 — CAN Bus Communicating Board/Dispiay Board Cable
- 454110190211 — Patient Table AC Power Cable
- 454110190222 — G-HOST Signal Cable1
- 454110190231 — Tilt Limit Switch Cable
- 454110190241 — PWM Board Power Supply Cable
- 454110190251 — Manual Control Board Power Cable
- 454110190261 — Rotation Control Signal Cable
- 454110190271 — Left Panel Power Cable
- 454110190281 — Left Emergency Switch Cable
- 454110190301 — Breath Navigation Board Cable
- 454110190311 — Host PC Network Cable
- 454110190321 — Connecting Network Cable
- 454110190331 — Brush Block Signal Interface Cable
- 454110190341 — Acquisition Pulse Cable
- 454110190351 — G-HOST Signal Cable 2
- 454110190361 — Patient table Signal Cable
- 454110190362 — Patient table Signal Cable
- 454110190371 — CTBOX Cable 1
- 454110190381 — CTBOX Cable 2
- 454110190431 — Cable of Interface Control card
- 454110190441 — Rotator System Cable ASSY
- 454110190471 — Laser Marker Cable1
- 454110190472 — Laser Marker Cable1
- 454110190481 — Laser Marker Cable2
- 454110190491 — Collimator driving Board Power Cable
- 454110190501 — Collimator driving signal Cable
- 454110190511 — Post-Collimator Board Cable
- 454110190521 — HV/Collimator Control Board Interface Connecting C
- 454110190531 — HV Control Cable1(MX6000)
- 454110190541 — HV Control Cable2(MX6000)
- 454110190551 — DAS Interface Board/Slip ring Interface Board Conn
- 454110190561 — DAS data Cable
- 454110190571 — MONITOR Board Cable
- 454110190581 — Pre-Collimator Control Cable
- 454110190591 — DAS Temperature Measurement Cable
- 454110190601 — Compensator Motor driver Cable
- 454110190602 — Compensator Motor driver Cable
- 454110190611 — Pre-Collimator driver Power Cable
- 454110190612 — Pre-Collimator driver Power Cable
- 454110190622 — DAS/ Detector Assy fan Cable1
- 454110190632 — DAS/ Detector Assy fan Cable2
- 454110190641 — Compensator Detection Board Cable
- 454110190651 — HV/Collimator Control Board and DAS Interface Boar
- 454110190672 — Link Cable
- 454110190771 — HV Control Cable1(MX4000)
- 454110190781 — HV Control Cable2(MX4000)
- 454110190901 — Patient Table Limit Switch Cable4
- 454110190911 — Patient Table Manual Switch Cable1
- 454110190921 — Patient Table Manual Switch Cable2
- 454110190931 — Elevator&Descent Motor Limite Switch Cable1
- 454110190941 — Elevator&Descent Motor Limite Switch Cable2
- 454110190951 — Interface Board Cable1
- 454110190952 — Interface Board Cable1
- 454110190961 — Patient Table Interface Board Cable2
- 454110190971 — Patient Table Interface Board Cable3
- 454110190981 — Patient Table Interface Board Cable4
- 454110190991 — Patient Table Speaker Cable
- 454110191051 — Cable Between Patient Table and Actuator Board
- 454110191061 — Cable Between Motion Control Board and Encoder
- 454110191071 — Cable Between Motion Control Board and Safty Board
- 454110191081 — Patient Table Electromagnetism Clutch Cable
- 454110191091 — CAN Interface Cable
- 454110191101 — Patient Table Level SERVO Motor Cable
- 454110191102 — Patient Table Level SERVO Motor Cable
- 454110191111 — Level SERVO Motor Signal Cable
- 454110191121 — Elevator&Descent Motor Cable
- 454110191131 — Patient Table Vertical Encoder Cable
- 454110191141 — 24V Power Suuply for Safety Board
- 454110191151 — Patient Table Grounding Cable1
- 454110191161 — Horizontal Servo Power Supply Cable
- 454110191171 — Patient Table Grounding Cable2
- 454110191201 — Rack Power Supply Cable
- 454110191203 — Pack Power Supply Cable, Ver.3
- 454110191232 — CTBOX console Interface Board Cable
- 454110191242 — HUB Power Supply Cable
- 454110191251 — CTBOX console Cable
- 454110191311 — Gantry AC Input Cable
- 454110191321 — Host DC Cable
- 454110191331 — Host AC Cable
- 454110191341 — Patient Table AC Power Cable
- 454110191351 — Rotation Servo Motor Power Cable
- 454110191361 — Filter Z102 Input Cable
- 454110191371 — G-HOST Power Input Cable
- 454110191381 — Top Cover Fan Cable1
- 454110191391 — Top Cover Fan Cable2
- 454110191401 — Rotation System Cable ASSY
- 454110191411 — Linear Input Power Cable
- 454110191421 — Filter Z202 Input Cable
- 454110191461 — Electricity Sensor Cable
- 454110191471 — DAS Temperature Control Board P.S. Cable
- 454110191481 — DAS Temperature Control Switch Cable
- 454110191491 — DAS Temperature Control Signal Cable
- 454110191561 — Nemoto Auto Enhance A-60 injector interface cable
- 454110191571 — Medtron 82 CT Injector interface cable
- 454110191671 — Medrad Vistron Injector Cable
- 454110191681 — Tyco CT9000 Injector Cable
About part numbers starting 45411019
Every listing in this 45411019 part-number group carries the OEM part number, part name and, where available, the FRU type and board-level notes, so you can match the exact revision fitted in your scanner before you order. Parts are supplied on exchange basis only against return of your original unit, and each unit is bench tested and packed in ESD-safe material before dispatch.
Compatibility is listed against Philips and GE CT scanner platforms that share this number series. Because Philips and GE re-use assemblies across generations, many boards, cables, detector modules and power components carry equivalent alternative numbers — send us the number stamped on your existing part and we will confirm the correct fit and any superseding revision.
Service availability covers all-India supply with field engineer support for installation, calibration and post-fit verification, plus AMC/CMC contracts, breakdown call-outs and exchange supply of tested assemblies. Share your system model and part number for current stock position, lead time and pricing.
Our engineers came out of the Philips Healthcare and GE Healthcare service organisations, so a part order can be paired with on-site fitment: fault confirmation before the part ships, replacement under proper ESD and high-voltage precautions, recalibration and image quality checks afterwards, and a signed service report with the readings recorded for your NABH and AERB documentation. All assemblies are supplied on exchange basis only — your original unit is returned to us — and we do not undertake board repair for customers.