CT spare parts by name: F
89 catalogue parts have names starting with F. Names that exist as several part numbers open a model chooser so you can match the right number to your CT system.
- Falcon Acquisitor 453566500811
- Fan Assembly M304 453566129841
- Fan Assy 455018001531
- FAN ASSY FOR HV TRAN.MX 453566427011
- Fan HV 453566499311
- FAN M305 M306 453566129581
- Fan with flying leads 453567385881
- Fan, Tube Axial 453566503142
- Fastener Ring External E-Style, 1/4 shaft 453567448591
- Fiber Assy. , Bi-Dir, Rotor, Transmit, 2 Fibers 453567102351
- Fiber Assy. Source, Rotor, Transmit 453567091121
- Fiber Assy., B-Dir, Transmit, Stator 453567102341
- Fiber Assy., Bi-Dir, Rotor Receive , 10 Fibers 453567098161
- Fiber Assy., Bi-Dir, Stator Receive, 5 Fibers 453567098171
- Fiber Assy., Data, Receive Stator, 4 Fibers 453567098181
- Fiber Opt.4 LC-LC + 1 SC-SC 455012305021
- Fiber Optic Cable (ADU to RCOM) W590 453567028711
- Fiber optic cable 4 LC-LC + 1 SC-SC 453567385841
- Fiber, Optic Single, GSU to RECON, 100 ft. 453567034411
- Filament Driver cable(MX4000) 454110215441
- FILLING AND DRANING VALVE MX 453566129461
- FILLING SET 455018001161
- FILTER FOR FAN(5 PIECES)MX 453566367352
- Filter Kit 454110076121
- FILTER SET(5 PIECES) MX 453566129371
- Filter Z102 Input Cable 454110191361
- Filter Z202 Input Cable 454110191421
- FIMI 18.1" Color LCD Monitor 991932051201
- Flat Headrest Extension Assy 453567417551
- FOC D514 453566500221
- Focus Tracing Detector 454110103201
- Foot Control, single-pedal 453567058051
- Foot Pedal Assembly 453567423491
- Foot Pedal Cover 455012001391
- Foot Pedal, Float Position 453567449411
- Foot Pedal, Load Position 453567449431
- Foot Pedal, Unload Position 453567449421
- FOOT SWITCH GANTRY-COUCH 455018001661
- Footswitch Cover Assy 453567066371
- Footswitch Inner (Lower) Cover 453567025601
- Footswitch Tableside Control PCB Assembly 453567430041
- FPGA Download Kit 2 part numbers — choose your model
- FRC Assembly 453567057163
- Frequency Convertor 453566496811
- Front 3 part numbers — choose your model
- Front Cover 2 part numbers — choose your model
- Front Cover Gas Spring, 175 lb. 453567055311
- Front Cover Gas Spring, 225 lbs 453567416831
- FRONT COVER MICROWITCH 453566129231
- Front Door Assembly 453567429781
- Front Door Assembly (magnetic latch) 453567383981
- Front Door Assembly (newer magnetic latch model) 453567401741
- Front Door Assembly (pin latch) 453567385641
- Front Door Hinge (fits all) 453567385681
- Front door lock support 453567385661
- Front door pin latch 453567385671
- Front Pall Cover 454110104751
- FSE Biohazar Kit 453567031671
- FT/SW Out (w870/5) 455012399021
- Functional Module CAN-bus 455018001351
- Funnel Cover 454110104781d
- Fuse 0 63A 250V Traeg 5X20 (F11) 453566499271
- FUSE 2A F2_F3 MX 453566129241
- Fuse 2A SB 453566503541
- Fuse 3 15A 250V Traeg 5X20 (F13) 453566499301
- Fuse 30A 455018001371
- FUSE 40A MX-F200 453566129632
- Fuse 50mA 250V Traeg 5X20 (F14) 453566499371
- FUSE 5A F1 MX 453566129381
- Fuse 5A SB 453567020391
- FUSE 80A MX -F100 453566129622
- Fuse and relay control (FRC) Assy 453567027482
- FUSE AT 63X32MM 453566376111
- Fuse F1 - F3, LPJ-20SP, 600V, 20A 453566501741
- Fuse F4 - F6, 600V, 2.5A, Timer Delay 453566146351
- Fuse Holder 453567055301
- Fuse holder, 2 pole, 600V, 30A 453567068171
- Fuse holder, 3 pole, 600V, 30A 453567068181
- Fuse holder, 3 pole, 600V, 60A 453567068191
- Fuse Kit 454110076081
- Fuse, F303, 20A 453566503121
- Fuse, F307, F306, 3A 453566039442
- Fuse, F308, 5A 453566145881
- Fuse, F310, F309, 2A 453566146661
- Fuses, 15A Type CC 453566503131
About CT parts named F
Every listing in parts whose name starts with F carries the OEM part number, part name and, where available, the FRU type and board-level notes, so you can match the exact revision fitted in your scanner before you order. Parts are supplied on exchange basis only against return of your original unit, and each unit is bench tested and packed in ESD-safe material before dispatch.
Compatibility is listed against Philips and GE CT scanner platforms. Because Philips and GE re-use assemblies across generations, many boards, cables, detector modules and power components carry equivalent alternative numbers — send us the number stamped on your existing part and we will confirm the correct fit and any superseding revision.
Service availability covers all-India supply with field engineer support for installation, calibration and post-fit verification, plus AMC/CMC contracts, breakdown call-outs and exchange supply of tested assemblies. Share your system model and part number for current stock position, lead time and pricing.
Our engineers came out of the Philips Healthcare and GE Healthcare service organisations, so a part order can be paired with on-site fitment: fault confirmation before the part ships, replacement under proper ESD and high-voltage precautions, recalibration and image quality checks afterwards, and a signed service report with the readings recorded for your NABH and AERB documentation. All assemblies are supplied on exchange basis only — your original unit is returned to us — and we do not undertake board repair for customers.